Contribution of the Provençal Well for the Improvement of the Thermal Comfort in the Building in Turbulent Regime

  •   Kokou N’wuitcha
  •   Ouro-Djobo Essoavana Samah
  •   Yendouban Kolani
  •   Magolmèèna Banna
  •   Belkacem Zeghmati

Asian Journal of Physical and Chemical Sciences, Volume 10, Issue 4, Page 41-68
DOI: 10.9734/ajopacs/2022/v10i4189
Published: 31 December 2022

  • View Article
  • Download
  • Cite
  • References
  • Statistics
  • Share

Abstract


In the current energy context, geothermal systems are highly developed in the building field. Among these interesting systems on the energy plan, one finds in particular the earth-to-air heat  exchanger commonly called ‘Canadian or Provençal well’. It consists of tubes buried in which the ambient air is pushed in order to be refreshed in contact with the ground whose temperature is quasi-constant throughout the year. In this work, a study of the performance of an earth-to-air heat exchanger was undertaken by means of numerical modeling of heat exchange by forced convection in a buried tube. The transfer equations in the tube are discretized using the finite volume method in turbulent regime and solved using the Thomas algorithm. For the determination of the ground temperature, the model of the semi-infinite mass subjected to a periodic excitation was adopted. The soil temperature was used as a boundary condition for the buried tube.

The results show that the interest of the earth-to-air heat exchanger is major, since it improves throughout the year, the thermal conditions sought. It intervenes in an effective way on the damping of the thermal amplitudes in the building. The variation of the diameter and the length of earth-to-air heat exchanger does not influence notably the distribution of the streamlines and isotherms but affect significantly the values of stream function and temperature inside de tube of the earth-to-air heat exchanger. When diameter of the pipe increases, the outlet temperature increases. The increase of the length of the earth-to-air heat exchanger leads to the isotherms increase as a result of the intensification of heat exchange between the walls and the convective jet. The temperature in the air outlet compartment is lower as the length of the earth-to-air exchanger increases.

Keywords:
  • Earth-to-air heat exchanger
  • canadian well
  • geothermal energy
  • building air conditioning
  • heat transfer
  • Full Article – PDF
  • Review History

How to Cite

N’wuitcha, K., Essoavana Samah, O.-D., Kolani, Y., Banna, M., & Zeghmati, B. (2022). Contribution of the Provençal Well for the Improvement of the Thermal Comfort in the Building in Turbulent Regime. Asian Journal of Physical and Chemical Sciences, 10(4), 41–68. https://doi.org/10.9734/ajopacs/2022/v10i4189
  • ACM
  • ACS
  • APA
  • ABNT
  • Chicago
  • Harvard
  • IEEE
  • MLA
  • Turabian
  • Vancouver
  • Endnote/Zotero/Mendeley (RIS)
  • BibTeX

References

Antinucci M. Fleury B, Lopez d’ Asiain J, Maldonado E, Santamomis M, Tombazis A, Yannas S. Passive and hybrid cooling of buildings-state of the art. Int. J. Solar Energy. 1992;11:251-272.

Santamouris M, Argiriou A, Vallindras M. Design and operation of a low energy consumption passive solar agricultural greenhouse. Solar Energy. 1994;52(5). DOI:https://doi.org/10.1016/0038-092X(94)90114-H

Bisoniya TS., Kumar A. Baredar P. Experimental and analytical studies of earth-air heat exchanger (EAHE) systems in India: a review. Renewable and Sustainable Energy Reviews. 2013;19:238–246. DOI:https://doi.org/10.1016/j.rser.2012.11.023

Lund JW, Freeston DH, Boyd TL. Direct application of geothermal energy: worldwide review. Geothermics. 2005;34(6):691-727 DOI:https://doi.org/10.1016/j.geothermics.2005.09.003

Bisoniya TS. Design of earth–air heat exchanger system. Geothermal Energy. 2015;3(1):1-0. DOI:https://DOI10.1186/s40517-015-0036-2

Santamouris M, Pavlou K, Synnefa A, Niachou K, and Kolokotsa D. Recent progress on passive cooling techniques. Advanced technological developments to improve survivability levels in lowincome households. Energy and Building. 2007; 39(7):859-866. DOI:https://doi.org/10.1016/j.enbuild.2007.02.008

Santamouris M, Gaitani N, Spanou A, Saliari M, Giannopoulou K et al. Using cool paving materials to improve microclimate of urban areas - Design realization and results of the flisvos project. Building and Environment. 2012;53: 28–136. DOI:https://doi.org/10.1016/j.buildenv.2012.01.022

Santamouris M, Synnefa A, Karlessi T. Using advanced cool materials in the urban built environment to mitigate heat islands and improve thermal comfort conditions. Solar Energy. 2011;85(12): 3085–3102.

DOI:https://doi.org/10.1016/j.solener.2010.12.023

Bisoniya TS, Kumar A, Baredar P. Experimental and analytical studies of earth– air heat exchanger (EAHE) systems in India: a review. Renewable and Sustainable Energy Reviews. 2013;19:238–46. DOI:https://doi.org/10.1016/j.rser.2012.11.023

Ozgener O, Ozgener L. Determining the optimal design of a closed loop earth to air heat exchanger for greenhouse heating by using exergoeconomics. Energy and Buildings. 2011;43(4):960-965. DOI:https://doi.org/10.1016/j.enbuild.2010.12.020

Florides G, Kalogirou S. Ground heat exchangers-a review of systems, models and application. Renewable Energy. 2007;32(15):2461–78. DOI:https://doi.org/10.1016/j.renene.2006.12.014

Vaz J, Sattler MA, dos Santos ED, Isoldi LA. Experimental and numerical analysis of an earth–air heat exchanger. Energy and Building. 2011;43(9):2476–2482.

DOI:https://doi:10.1016/j.enbuild.2011.06.003

Li H, Yu Y, Niu F, Michel S, Chen B. Performance of a coupled cooling system with earth-to-air heat exchanger and solar chimney. Renewable Energy. 2014;62:468–477. DOI:https://doi.org/10.1016/j.renene.2013.08.008

Selamat S, Miyara A, Kariya K. Numerical study of horizontal ground heat exchangers for design optimization. Renew. Energy. 2016;95:561–573. DOI:https://doi.org/10.1016/j.renene.2016.04.042

Sodha MS, Mahajan U, Sawhney RL. Thermal performance of a parallel earth air-pipes system. Int. J. Energy Res. 1994;18:437-447. DOI:https://doi.org/10.1002/er.4440180404

Thiers S. Bilans Energétiques et Environnementaux de Bâtiments à Energie Positive. PhD thesis, Ecole Nationale Supérieure des Mines de Paris, November 2008.

De Paepe M, Janssens A. Thermo-hydraulic design of earth-air heat exchangers. Energy and Buildings. 2003;35(4):389-397. DOI:https://doi.org/10.1016/S0378-7788(02)00113-5

Badescu V, Sicre B. Renewable energy for passive house heating: II. Model. Energy and Buildings. 2003;35(11):1085–1096. DOI:https://doi.org/10.1016/S0378-7788(02)00113-5

Mathur A, Mathur S, Agrawal GD;Mathur J. Comparative study of straight and spiral earth air tunnel heat exchanger system operated in cooling and heating modes. Renewable Energy. 2017;108:474-487 DOI:https://doi.org/10.1016/j.renene.2017.03.001

Benrachi N, Ouzzane, M, Smaili A, Lamarche L, Badache M, Maref W. Numerical parametric study of a new earth-air heat exchanger configuration designed for hot and arid climates. Int. J. Green Energy. 2020;17:115–126. DOI:https://doi.org/10.1080/15435075.2019.1700121

Kanaris AG, Mouza AA, Paras SV. Flow and heat transfer predicition in a corrugated plate heat exchanger using a CFD code. Chemical Engineering & Technology. 2006;29(8):923-930. DOI:https://doi.org/10.1002/ceat.200600093

Wang Y, Dong Q, Liu M, Characteristic of fluid and heat transfer in shell side of heat exchangers with longitudinal flow of shell side fluid with different supporting structures. Proceedings of International Conference on Power Engineering. 2007; Hangzhou, China.

Kabashnikov VP, Danilevskii LN, Nekrasov VP and Vityaz IP. Analytical and numerical investigation of the characteristics of soil heat exchanger for ventilation systems. International Journal of Heat and Mass Transfer. 2002;45:2407-2418. DOI:https://doi.org/10.1016/S0017-9310(01)00319-2

Paepe MD, Janssens A. Thermo-hydraulic design of earth-air heat exchangers. Energy and Buildings. 2003;35(4):389-397. DOI:https://doi.org/10.1016/S0378-7788(02)00113-5

Zhou J, Wang H, Li X, Dai C. Experimental investigation and theoretical model of heat transfer of saturated soil around coaxial ground coupled heat exchanger. Applied Thermal Enginnering. 2008;28(2-3):116-125. DOI:https://doi.org/10.1016/j.applthermaleng.2007.03.033

Tittelein P, Achard G, Wurtz E. Modelling earth-to-air heat exchanger behaviour with the convolutive response factors method. Applied Energy. 2009;86(9):1638-1691. DOI:https://doi.org/10.1016/j.apenergy.2009.02.010

Ramırez L, Xaman JAJ, Alvarez G, Hernandez P. Numerical study of earthto-air heat exchanger for three different climates. Energy and Buildings. 2014; 76:238-248. DOI:https://doi.org/10.1016/j.enbuild.2014.02.073

Flaga M, Schnotale J, Radon J, Was K. Experimental measurements and CFD simulation of a ground source heat exchanger operating at a cold climate for a passive house ventilation system. Energy and Buildings. 2014;68:562-570. DOI:https://doi.org/10.1016/j.enbuild.2013.09.008

Cucumo M, Cucumo S, Montoro L, Vulcano. A dimension transient analytical model for earth-to-air-heat exchangers, taking into account condensation phenomena and thermal perturbation from the upper free surface as well as around the buried pipes. International of Heat and Mass Transfer. 2008;51(3-4):506-916.

DOI:https://doi.org/10.1016/j.ijheatmasstransfer.2007.05.006

Sehli A, Hasni A, Tamali M. The potential of earth-air heat excahngers for low energy cooling of buildings in South Algeria. Enegy Procedia. 2012;18:496-506. DOI:https://doi.org/10.1016/j.egypro.2012.05.061

Patankar SV. Numerical heat transfer and fluid flow. Hemisphere Publishing Corporation; 1980.

Patankar SV, Spalding DB. A calculation procedure for heat, mass and momentum transfer in three-dimensional parabolic flows. Int. J. Heat Mass Transf. 1972; 15(10)1787–1806.

DOI:https://doi:10.1016/0017-9310(72)90054-3

Ampofo F, Karayiannis TG. Experimental benchmark data for turbulent natural convection in an air filled square cavity. Int. J. Heat Mass Transf. 2003;46(19)3551–3572.

DOI:https://doi:10.1016/S0017-9310(03)00147-9.

Henkes RAWM, Hoogendoorn CJ. Comparison exercise for computations of turbulent natural convection in enclosures. Numer. Heat Transf. Part B Fundam. 1995. 28(1)59–78 DOI:https://doi:10.1080/10407799508928821

  • Abstract View: 49 times
    PDF Download: 25 times

Download Statistics

  • Linkedin
  • Twitter
  • Facebook
  • WhatsApp
  • Telegram
Make a Submission

Information

  • For Readers
  • For Authors
  • For Librarians

Current Issue

  • Atom logo
  • RSS2 logo
  • RSS1 logo


Copyright © 2010 - 2023 Asian Journal of Physical and Chemical Sciences. All rights reserved.